PRODUCT UPDATES
|
Get 150% More Test Results,
Insuring The Quality Of Your Starters & Solenoids
Using Our M151-06-2000
Currently you might be reading Amps & Volts,
By Using the M151-06-2000 you will now be able to read
Volts, Amps, Solenoid Pull In Time, Solenoid Release Time and Contact
Voltage Drop
....ALL IN 4 SECONDS
|

|
3710
Riverside Drive
Crystal Lake, IL 60014
800-662-6099
815-459-0355
Fax:
815-459-0442
|
BACK
|
Check all the
mechanical movements and electrical contact voltage drop in seconds and
be sure for the first time since you became a rebuilders that all these
parts are working correctly together.
|
|
|

|
Outstanding
Features:
• Test mechanical and electrical points that have
never been tested before
• Hook Up Time: less than one minute to your
test bench.
• Can be left connected to your existing starter
tester for free run and/or load tests
• Display: Reading stays on after the test and
resets with the next test for easy quality evaluation
• Construction: Rugged High Impact Case
• Can be connected to your test bench, a battery or
your power supply
• Power: 12V, 24V & 32V DC capable
• Can be used with Free Run or Load
testers...Note: Voltage Drop Test Readings will be much higher on
load testers
• Microprocessor Controlled
• Only 4 connections necessary to the starter and
solenoid
|
Connecting
Test Leads
Color: Connection Point
Red on back : Test bench, battery, or power supply Red+
Red on front: Battery Stud on solenoid
Black: Starter case or mounting bolt at starter (ground -)
Blue: Field stud on solenoid
White: S Terminal on solenoid
To test after connectiong test leads, simply push the red button and
hold for 4 seconds to activate.
The readings will appear and stay on the screen until the next test.
|

|
Display Reading: Indications
and recommended readings
Voltage:
Voltage at battery cable, then voltage during test cycle.
Operate Time:
This is the time it takes (in seconds) for the contact to be made
between the contact
disk, battery and field stud
after the S-Terminal is activated. (This reading should be below
0.5 seconds. The lower the better.)
Release time:
The time (in seconds) it takes for the contact to break from the
battery and field stud after the S-Terminal is deactivated. (This
reading should be below 0.5 seconds. The lower the better.)
Voltage Drop:
The voltage drop across the Battery Stud, Contact Disk and Field
Stud. (This reading should be below 0.5 Volts. The lower
the better.) Under load test this reading will be higher.
Amps:
The amp draw of the starter and solenoid during the test.
|
Physical
Specifications:
Height: 4”
Width: 10”
Depth: 11”
Shipping Weight: Approximately 10 lbs.
Lead Length: 4 ft.