eagle PRODUCT UPDATES
Get 150% More Test Results,
Insuring The Quality Of Your Starters & Solenoids
Using Our M151-06-2000

Currently you might be reading Amps & Volts,
By Using  the M151-06-2000 you will now be able to read
Volts, Amps, Solenoid Pull In Time, Solenoid Release Time and Contact Voltage Drop
....ALL IN 4 SECONDS
M151-06-2000
3710 Riverside Drive
Crystal Lake,  IL   60014
800-662-6099
815-459-0355
Fax:
815-459-0442
AmEx
Visa
masterCard
BACK
Check all the mechanical movements and electrical contact voltage drop in seconds and be sure for the first time since you became a rebuilders that all these parts are working correctly together.

Parts Layout
Outstanding Features:
•    Test mechanical and electrical points that have never been tested before
•    Hook Up Time:  less than one minute to your test bench.
•    Can be left connected to your existing starter tester for free run and/or load tests
•    Display:  Reading stays on after the test and resets with the next test for easy quality evaluation
•    Construction:  Rugged High Impact Case
•    Can be connected to your test bench, a battery or your power supply
•    Power:  12V, 24V & 32V DC capable
•    Can be used with Free Run or Load testers...Note:  Voltage Drop Test Readings will be much higher on load testers
•    Microprocessor Controlled
•    Only 4 connections necessary to the starter and solenoid
Connecting Test Leads
Color:  Connection Point
Red on back :  Test bench, battery, or power supply Red+
Red on front:  Battery Stud on solenoid
Black:  Starter case or mounting bolt at starter (ground -)
Blue:  Field stud on solenoid
White:  S Terminal on solenoid

To test after connectiong test leads, simply push the red button and hold for 4 seconds to activate.
The readings will appear and stay on the screen until the next test.
Sample Reading
Display Reading:  Indications and recommended readings

Voltage:  Voltage at battery cable, then voltage during test cycle. 

Operate Time:  This is the time it takes (in seconds) for the contact to be made between the contact                 disk, battery and field stud after the S-Terminal is activated.  (This reading should be below 0.5 seconds.  The lower the better.)

Release time:  The time (in seconds) it takes for the contact to break from the battery and field stud after the S-Terminal is deactivated.  (This reading should be below 0.5 seconds.  The lower the better.)

Voltage Drop:  The voltage drop across the Battery Stud, Contact Disk and Field Stud.  (This reading should be below 0.5 Volts.  The lower the better.) Under load test this reading will be higher.

Amps:  The amp draw of the starter and solenoid during the test.
Physical Specifications:
Height:  4”
Width:  10”
Depth:  11”
Shipping Weight:  Approximately 10 lbs.
Lead Length:  4 ft.
Electrical Power:  12V, 24V & 32 V DC